BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//INFN-LNF - ECPv5.14.2.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:INFN-LNF
X-ORIGINAL-URL:https://w3.lnf.infn.it
X-WR-CALDESC:Eventi per INFN-LNF
BEGIN:VTIMEZONE
TZID:Europe/Rome
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20190331T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20191027T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/Rome:20191003T143000
DTEND;TZID=Europe/Rome:20191003T160000
DTSTAMP:20260829T210049
CREATED:20190724T184826Z
LAST-MODIFIED:20191010T184727Z
UID:20306-1570113000-1570118400@w3.lnf.infn.it
SUMMARY:Boron Neutron Capture Therapy: status and Novosibirsk solution
DESCRIPTION:At present\, Boron Neutron Capture Therapy (BNCT) is considered to be a promising method for the treatment of tumors. The report presents the basics of BNCT\, its development stages\, the state of development of accelerator neutron sources for BNCT clinics and describes in detail the Novosibirsk accelerator neutron source. This source is a state-of-the-art device comprised of i) the Vacuum Insulation Tandem Accelerator (VITA) – a new type of charged particle accelerator\, ii) an advanced solid lithium target with superior resistance to blistering\, and iii) a neutron Beam Shaping Assembly. At VITA characterized by a high acceleration rate of charged particles a stationary proton beam with an energy of 2.3MeV and a current of 9 mA\, sufficient for therapy\, was obtained. A neutron-producing target optimal for forming an epithermal neutron flux that meets the requirements of BNCT has been developed and experimentally studied. To confirm the required quality of the neutron beam\, the effect of neutron radiation on cell cultures and laboratory animals was studied. In the near future\, it is planned to prepare a “handmade” Novosibirsk source for conducting therapy and to implement BNCT in 2022. The Novosibirsk source became the prototype source being built for the clinic in Xiamen (China) – one of the first five BNCT clinics. In addition to being used in BNCT\, the source was used to determine dangerous impurities in ceramics for ITER and is planned to be used for radiation testing of the optical fiber and photomultiplier for CERN. In the latter case\, the hydrogen beam will be replaced by a deuterium one. The report gives the construction of the source\, presents the results of the research and declares the plans.
URL:/event/boron-neutron-capture-therapy-status-and-novosibirsk-solution/
LOCATION:Aula Salvini
CATEGORIES:Seminari generali
END:VEVENT
END:VCALENDAR